ProAct Treatment Equipment
Specification Sheet
Dual Phase Extraction System
ProAct DPES 500 w/OW Separator & Air Stripper
Featuring the "ProAct Advantage"
| General Specification: | Liquid Ring Pump w/Oil-Water Separator, Air Stripper, Bag Filters, Carbon Adsorbers |
|
|
500 ACFM @28” Hg |
|
|
5 GPM water treatment |
|
Trailer Size: |
8 ft wide x 24ft long x 10ft height |
|
|
7,000 pounds double axle trailer |
|
Main Equipment: |
40 Hp Oil sealed Liquid Ring Pump |
|
|
240 gallon knock out tank w/clean out port |
| 5 GPM XP 3/4 Hp Moyno pump | |
| 10 GPM Oil/water separator | |
| 55 gallon product collection drum | |
| 10 GPM XP ½ Hp water transfer pump | |
| 10 GPM Air stripper with blower | |
| 10 GPM XP 1 Hp transfer pump | |
| 2-LCO8 Rosedale bag filters | |
| 2-200 pound granular activated carbon adsorbers | |
|
|
ERCO flow meter (air) |
|
|
Totalizing water flow meter |
|
|
Vacuum and pressure gauges, sample ports |
|
Trailer Specifications |
XP lights, Heater, fan in equipment room |
| Components in equipment room wired for XP conditions | |
| Non XP lights, control panel in control room | |
| Outside light | |
|
Control Panel Specifications: |
PLC (Program Logic Controller) |
| HAO switch all components | |
|
|
Emergency stop button |
|
|
Fault lights and reset |
|
|
GFI |
|
Inlet hose connections: |
4 male camlock1” inlet fittings (4 well manifold including site glass, flow meter, vacuum gauge, flow control valve) |
|
Outlet hose connections: |
4” air stack for LRP exhaust (18 ft ht.) |
|
|
Vapors can be plumbed for off-gas treatment |
|
|
1” male camlock water discharge |
|
Power requirement: |
230 volt, 3 phase, 200Amp service (Main fused disconnect located outside trailer) |
Contact ProAct at 231-843-2711 Fax 231-843-4081 or ProActAdvantage@proact-usa.com