ProAct Treatment Equipment Specification Sheet      

Dual Phase Extraction System                    

ProAct DPES 200 w/ OW Separator & Air Stripper    

Featuring the "ProAct Advantage"                  

General Specification: Liquid Ring Pumps w/Oil-Water Separator, Air Stripper, Bag filters and Carbon Adsorbers 

 

200 ACFM @ 28” Hg

 

5 GPM water pump  

Trailer Size:

8 ft wide x 24ft long x 10ft height

 

7,000 pounds double axle trailer

Main Equipment:

Two 7.5 Hp Oil sealed Liquid Ring Pumps 

 

120 gallon knock out tank w/clean out port 

 

 5 GPM XP 3/4 Hp Moyno pump

  10 GPM Oil/water separator
  55 gallon product collection drum
  10 GPM XP ½ Hp transfer pump
  10 GPM Air stripper with blower
  10 GPM XP 1 HP transfer pump
  2-LCO8 Rosedale bag filters
  2-200 pound granular activated carbon adsorbers
  ERCO flow meter (air)

 

Totalizing water flow meter

 

Vacuum and pressure gauges, sample ports

 Trailer Specifications

XP lights, Heater, fan in equipment room

  Components in equipment room wired for XP conditions
  Non XP lights, control panel in separate control room
  Outside light   

Control Panel Specifications:

PLC (Program Logic controller)

  HAO switch all components 

 

Emergency stop button  

 

Fault lights and reset

 

GFI

Inlet hose connections:

3 male camlock 1” inlet fittings (4 well manifold including site glass, flow meter, vacuum gauge, flow control valve)

Outlet hose connections:

2” air stack for LRP exhaust (18 ft ht.)

 

Vapors can be plumbed for off-gas treatment

 

1” male camlock water discharge

Power requirement:

230 volt, 1 phase, 100Amp service (Main fused disconnect located outside trailer)

            Contact ProAct at 231-843-2711   Fax 231-843-4081  or  ProActAdvantage@proact-usa.com