ProAct Treatment Equipment
Specification Sheet
Thermal Catalytic Oxidizer
ProAct TCO 100
Featuring the "ProAct Advantage"
|
General Specification: |
Thermal/Catalytic Oxidizer |
|
|
Propane or Natural Gas |
|
|
100 SCFM @6”Hg |
|
Trailer Size: |
8 ft wide x 10 ft long x 9ft height |
|
|
2500 pounds double axle trailer |
|
Main Equipment: |
5 Hp XP Blower |
|
|
Flame arrestor |
|
|
Heat Exchanger |
| Burner (100,000 BTU/Hr) | |
| Stainless Steel Reactor | |
| Catalyst | |
|
|
Circular Chart Recorder (Inlet and Outlet Temperatures) |
|
|
Vacuum and pressure gauges, sample ports |
|
Trailer Specifications |
System is mounted on back of a flat bed trailer |
|
Control Panel Specifications: |
PLC (Program Logic controller) |
|
|
On/Off Switch all components |
|
|
Emergency stop button |
| Fault lights and reset | |
|
|
Interlock connections |
|
Inlet hose connections: |
1 Male camlock 2” inlet fitting (30 ft hose w/system) |
|
|
Auto dilution valve |
|
Outlet hose connections: |
6” air stack from top of enclosure (15 ft ht) |
|
Power requirement: |
230 volt, 3 phase, 30 Amp service (20 ft electrical cord) |
|
|
Propane or Natural Gas connection |
Contact ProAct at 231-843-2711 Fax 231-843-4081 or ProActAdvantage@proact-usa.com