ProAct Treatment Equipment Specification Sheet      

Thermal Catalytic Oxidizer                     

ProAct TCO 100                             

Featuring the "ProAct Advantage"                 

General Specification:

Thermal/Catalytic Oxidizer  

 

Propane or Natural Gas

 

100 SCFM @6”Hg

Trailer Size:

8 ft wide x 10 ft long x 9ft height

 

2500 pounds double axle trailer 

Main Equipment:

5 Hp XP Blower

 

Flame arrestor

 

Heat Exchanger

  Burner (100,000 BTU/Hr)
  Stainless Steel Reactor
  Catalyst

 

Circular Chart Recorder (Inlet and Outlet Temperatures)

 

Vacuum and pressure gauges, sample ports

 Trailer Specifications

System is mounted on back of a flat bed trailer 

Control Panel Specifications:

PLC (Program Logic controller)

 

On/Off Switch all components

 

Emergency stop button

  Fault lights and reset

 

Interlock connections

Inlet hose connections:

1 Male camlock 2” inlet fitting (30 ft hose w/system)

 

Auto dilution valve

Outlet hose connections:

6” air stack from top of enclosure (15 ft ht)

Power requirement:

230 volt, 3 phase, 30 Amp service (20 ft electrical cord)

 

Propane or Natural Gas connection

            Contact ProAct at 231-843-2711   Fax 231-843-4081  or  ProActAdvantage@proact-usa.com